Tests of hybrids circuits for the CMS tracker : FHIT project
Front end Hybrid Industrial Tester (FHIT)
In collaboration with the RWTH Aachen III university and the IReS in Strasbourg, we are in charge of developping a tester for Front End Hybrids (FEH). This device will be able to perform automatically and quickly (about 1 min) a full industrial test which consist in an connectivity test, an electrical and a functional test. The first two tests are performed by the FHIT board itself (firmware level) while the functional test is performed by the ARC board, inside the FHIT box, through a C++ developped software. This C++ code comes from ARCS (RWTH Aachen) and is interfaced through a LabVIEW software. This software, called FHITS, allows a fully automatic use of FHIT, with features like power supply automatic control, barcode scanner reading and result files creation.
dual-FHIT with two FEHs  Contact : lemaitre@fynu.ucl.ac.be
Status:
- FHITS 3.01 has been released and is available for download. [30/11/04]
- LFHIT user manual available [cds]
- XML translator 1.31b is available.
- Firmware rev300 (30/04/04) is also available for download [18/01/05].
Downloads:
- FHITS (screenshots : 1, 2, 3)
- V3.01 compatible with firmware rev24 and greater
- executable [zip] 0.6Mb [30/11/04]
- installer : [zip] 1.1Mb [30/11/04]
- installer with LabView RunTime Engine : [zip] 12.6Mb [30/11/04]
- Firmware
- XML converter
- XML converter 1.31 beta [exe] 49Kb (xml.exe) [09/03/04] : compatible with production database
- XML file example
- Sources :
- FHITS 3.01 [zip] 1.7Mb [30/11/04],
- Firmware v2.46[zip] 28Kb (fhit.c ; putchar.c) [17/12/03]
- XML translator 1.31b[zip] 27Kb (including html version) [18/07/03]
- Utilities :
Documents:
- FHIT
- Hybrids
- Cahier des clauses techniques particulières [doc] 2Mb [pdf] 3Mb (in french)
- "CMS Tracker PLL Reference Manual", V 2.0, 07/2000, [pdf]
- "DCU2 User Guide", V 2.16, 10/10/2001, [pdf]
- "APVMUX User guide", V 1.0, 9/5/2000, [pdf]
- "APV25-S1 User GuideVersion", V 2.2, 5/9/2001, [pdf]
- "Design and results from the APV25, a deep sub-micron CMOS front-end chip for the CMS tracker", [pdf]
Talks:
- CMS Week 10.12.2003 (X. Rouby) [cds]
- Tracker Week xx.10.2003 (V. Lemaitre) [pdf] 0.5Mb
- CMS Week 03.06.2003 (X. Rouby) [cds]
- Tracker Week 29.01.2003 (V. Lemaitre) [cds]
- Strasbourg meeting 20.11.2002 (X. Rouby) [cds]
- Tracker Week 23.10.2002 (X. Rouby) [cds]
- Tracker Week 17.07.2002 (X. Rouby) [cds]
- Diploma thesis 26.06.2002 (X. Rouby) [cds]
- Tracker Week 24.04.2002 (V. Lemaitre) [cds]
- CMS Week 24.09.2001 (V. Lemaitre) [cds]
- CMS Week 11.07.2001 (V. Lemaitre) [pdf] 0.92Mb
Links :
- RWTH Aachen III : ARC web page
- Module Test Working Group (MTWG)
- CMSDoc
- Tracker Electronics (TKEL)
- CMS Tracker Database (DB)
- Agenda CERN
updates :
FHITS Version 1.4 (LabVIEW only): [26/03/03]
- FHIT_PowerSupply2.vi has been modified, in order to set
- the current limit to 3.0 A (previously 2.6 A)
- the power supply voltage to 5.09 V (previously 5 V)
(system:remote;*rst;*cls;:apply P25V,12.0,0.2;apply N25V,-5.0,0.2;apply P6V,5.09,3;output on;)
- Industrial_test.vi has been modified
- there is a new vi (getCurrentPath.vi) aiming at selecting the current path either in .vi or .exe mode, in order to find the path of 'FHIT_PedNoi.dat' file.
(see 1[0..2] -> loop -> true -> 1[0..1] -> 0[0..1] -> False -> 2 [0..2] -> True "Reading the file with data from FT subtests" ) The code is neater and more efficient.
FHITS Version 1.41 (LabVIEW only): [02/04/03]
- FHIT_PowerSupply2.vi has been modified, in order to set
- the current limit to 3.4 A (previously 3.0 A)
- Industrial_test.vi has been modified
- The error from General parameter on FHIT 2 (dual-FHIT setup) has been fixed.
FHITS Version 1.42 (LabVIEW only): [end 05/03] available at CERN only
- There are some modification to allow non serial port barcode scanner compatibility
FHITS Version 1.43 (LabVIEW only): [end 06/03]
- This does not integrate the modification for compatibility with non serial barcode scanner
- This version has a patch that converts new part numbers into compatible old part number.
This is a temporary patch which will be removed once the firmware has been updated
FHITS Version 1.44 (LabVIEW only): [04/07/03]
- Merges the versions 1.42 and 1.43
- Changes in the result indicator : the hybrid barcode and the position of this hybrid on the FHIT is displayed
eg "Hybrid grade A (30216631200123 on FHIT1)"
- Installed in Louvain, Strasbourg, CERN and the industry
FHITS Version 1.45 (LabVIEW only): Available [06/08/03]
- "Operator tag" bug in configuration file solved
- Minor display changes
FHIT Version 2.0 (all aspects)
- Firmware (rev20) :
- integration of new part numbers and minor changes.
- No limits on values from electrical test.
- LabVIEW (FHITS 2.0) :
- modifications relative to remarks from users
- reset button for insertion number
- screen shots jpg jpg jpg
- XML routine (1.0) : compatible with production DB [no changes]
- Mechanical aspects : available for industry only ; allow I_DET measurements
- New release of the reference guide ...coming soon
FHITS Version 2.1 (LabVIEW only): not released
FHITS Version 2.2 (LabVIEW only): not released
FHITS Version 2.3 (LabVIEW only): [14/11/03]
- Configuration file changes (Test Center, IDET test,...)
- Display changes : new 'Configuration' tag with display of FT parameters
- Bug removal for the output of tests with CT/ET fatal errors
- Output changes in ASCII .log file, with summarizing header
- 'Mono-FHIT on FHIT 2' mode available
- Code deeply cleaned
- Screenshots : 1, 2, 3
- Compatible with new firmware (rev23 is better) and runs ARCS 5.x .dll files.
FHITS Version 2.4 (LabVIEW only): Available [12/12/03]
- Configuration file changes (Electrical test limits)
- Display changes : new ET subtest LEDs
- Output changes in ASCII .log file
- Screenshots : 1
- Compatible with new firmware (rev24 is better) and runs ARCS 5.x .dll files.
- should be run with firmware rev24 (2.42) and XML-converter 1.3
FHITS Version 2.45 (LabVIEW only + firmware rev2.46): Available [17/12/03]
- Removal of bug on electrical test limits
- Screenshots : 1
- Compatible with firmware rev24 and runs ARCS 5.x .dll files.
- should be run with firmware rev246 or higher and XML-converter 1.3
FHITS Version 2.5 (LabVIEW only): Available [20/04/04]
- Removal of bug on CT/ET/SMB-test output
- Removal of bug (some FHITS LEDs does not light sometimes)
- Compatible with firmware rev24 and runs ARCS 5.x .dll files.
- should be run with firmware rev246 or higher and XML-converter 1.3
FHITS Version 2.5b (LabVIEW only): Available [22/06/04]
- Removal of bug on ET-test "out of range error"
- Compatible with firmware rev24 and runs ARCS 5.x .dll files.
- should be run with firmware rev246 or higher and XML-converter 1.3
FHITS Version 3.01 (LabVIEW only): Available [30/11/04]
- Change in configuration files : APVregister.cfg and FHITS.cfg instead of ITS_init.cfg (3.0)
- Allow the choice of APV register values (3.0)
- New 4th tab with detailed tables on ET results (3.0)
- Some minor bug removals for CT-only, Y and SMD modes (3.0)
- Compatible with firmware rev24 and runs ARCS 5.x .dll files. (3.0)
- should be run with firmware rev246 or higher and XML-converter 1.3 (3.0)
- Bug removal with "Y" option (3.01)
- Some improvement in display of the 4th tab (3.01)
XML translator 0.1 (executable) [24/04/03]
- xml.exe : converts every ".log" (ASCII) file into ".xml" file in the current directory : only for "good" hybrids
XML translator 0.2, 0.3, 0.4 (executable) [16/07/03]
- some xml tags have been changed : only for "good" hybrids
XML translator 1.0 (executable) [18/07/03]
- some xml tags have been changed
- compatible with any hybrid log file (ie, good or bad hybrids)
- compatible with the production data base : xml files could be uploaded with BigBrowser (not yet tested )
XML translator 1.1 (executable) Not released...
- some xml tags have been changed
XML translator 1.2 (executable) Foreseen [01/12/03]
- some xml tags have been changed
XML translator 1.3 (executable) [01/01/04]
- some xml tags have been changed or added
- deeper compatibility with old files
- compatible with the 3 tables : FHITProduction, FHITReception, FHITQA
XML translator 1.3 (executable) Available [09/03/04]
- tag problem with FHITQA database has been fixed
|